Telemetry and monitoring

Monitoring, Telemetry and Cost distribution

Cost Distribution in Shopping malls
-Measurement and individual access for each condominium
-Consolidation of all expenses items effectively verified
-Calculation of the energy cost (in R $/KWh) to be prorated by the units
-Application of this cost (in R $/kWh) on the consumption of each unit

Sectoral measurements in industries
-Estimation of energy costs per sector or production line
-Definition of targets by sector, motivating efficient consumption actions
-Identification of abnormal consumption to detect fraud and waste
-Application of this cost (in R $/kWh) on the consumption of each unit
-Standardisation of consumption per production unit/hours worked

Monitoring via Internet

 

Various models of meters: 
-Direct or indirect measurement
-Models with or without display
-Models for door mounting or panel background
-Compact TCs type “split-core”

Various communication technologies:
-Modbus protocol in RS-485 networks
-Internet access via GPRS-3G-4G-Ethernet
-Sigfox IoT

Catalog

ELO4550Q Portable Power Quality Analyzer

The ELO4550Q Power Quality Analyzer is a portable meter suitable for roving measurements that has technical and mechanical characteristics that provide the best results in this type of application.
The ELO4550Q measures Active and Reactive Electrical Energy in three-phase networks with class 0.2% of the bottom of the scale. Measurement occurs through the use of the accessories that come with the Analyzer. They are cables with Rugowski type current transformers for maximum current of 50 A, 500 A or 5000 A and cables for the voltage inputs of 30 V to 500 V in alternating current.
The intended application takes this analyzer to degree of protection IP65. The panel with the display, programming keys and communication interface are housed by the airtight lid that this analyzer has. Alternatively this enclosure may have a tab for attaching the analyzer to the installation site through tapes.
The ELO4550Q meter has a communication interface – Ethernet port. It also has mass memory to store measured quantities and events. The meter can be accompanied by a program to perform the communication and the collection of the recorded data.
The measurement and recording of active and reactive energy occur in the four quadrants (bidirectional) l.

Download

Catalog

ELO577 / ELO578

High Insulation TX Optical Interface Cable

The High Isolation Interface has been developed to enable the connection of supervision systems to electronic energy meters that have the Serial User Output in accordance with ABNT NBR 14519, such as ELO2113 and ELO2180.

The function of this interface is to ensure insulation between the meter and the data acquisition system, while preserving the integrity of the meter.

The interface consists of the ELO577 emitter cable and the ELO578 receiver cable.

The ELO577 emitter cable has a red LED that allows the installer to verify the data transmission that the meter is making through its Serial User Output.

The ELO577 / ELO578 High Isolation Interface is also provided along with the ELO548 and ELO2148 units.

Product benefited by the Informatics Legislation. (Article 48 of Decree No. 5.906 / 06).

Download

Manual

Technical Characteristics

Broadcast Cable ELO577:
• Temperature: 0 to + 60ºC.
• Humidity: 0 to 95% without condensation.
• Emission element: infrared emitter.
• For warm use.

Receiver cable ELO578:
• Temperature: 0 to + 60ºC.
• Humidity: 0 to 95% without condensation.
• Reception element: crystalline phototransistor.
• For warm use.

Connectivity

The terminals of the ELO577 emitter cable should be connected to the SU + and SU- terminals of the meter. The terminals of the ELO578 receiver cable should be connected to the terminals recommended by the receiving equipment (ELO548 and ELO2148).

Dimensions/Weight

Dimensions for each cable:
Length: 1 meter.
Weight: 0.073 kg.

FRATELO

Complete Power Analyzer. Allow diagnostics on the operating conditions and connection of the measurement set.

Fratelo is the portable field inspection meter. Its electrical and physical characteristics are better for the user to perform inspections on electrical energy measurements, from consumer units in general.

As an electronic multifunction meter it replaces to a large advantage conventional devices used as voltmeters, ammeters, phasors, wattmeters, standard meters, etc.

Operating as a complete power analyzer and incorporating the functions of a modern “standard meter”, it allows for quick and efficient diagnostics of the operating conditions and connection of the measuring set.

It is a valuable tool for maintenance centers, laboratories, measurement service providers and technical education institutions.

Main Features

Multimeter of electrical quantities.
Portable, lightweight and compact.
Measures and records all data from the “Fiscal Page” ®.
It surveys and records metrological “errors” of Wh and varh meters, single-phase, two-phase or three-phase, electronic or electromechanical, star or delta connection.
Potential circuit: 40 to 300 V ac (phase and neutral).
Current circuit: 0.01A to 100A, using external current transformers, appropriate “CLAMPS” calibrated in conjunction with the instrument.
Optionally special, external, high accuracy sensors can be supplied – manufacture “ELO”, range from 0.1 to 120A.
It can operate autonomously or computer-assisted.
It has autonomy to store up to 2000 records.
Extra light weight – weighs only 1,350 gr.

Alimentation

Independente e monofásica ou interna e trifásica.
80 a 300 V ca.
100 a 300 V cc.

Accuracy

For connection with special ELO sensor:

Wh 0.25% / (F.P)
Varh: 0.4%
Other quantities: 0.5%

With the use of calibrated “CLAMPS”

Wh: 0.5% / (F.P)
Varh: 1.0%
Other quantities: 1%

Dimensions

144mm x 144mm x 162mm

Product benefited by the Informatics Legislation. (Article 48 of Decree No. 5.906 / 06).

Download

Software

Manual

ELO 50

Program for the analysis of Readings of files have the format at (@)

The ELO.50 is a data analysis program contained in meter readings and ABNT standard electric energy recorders used in electric billing. It can analyze bidirectional meter information, standard ABNT.

The program generates reports and graphs for analysis, video or printer, showing the load curve, energy totalizers, power failures and fiscal page of the meters that record this information.

The ELO.50 offers complete accuracy in the verification of the readings, guaranteeing the highest reliability and quality of service to the energy concessionaires and, consequently, to its consuming customers.

The analyzes made are based on three-phase rules in force in Brazil.

Installation Requirements

  • PC-type microcomputer (Pentium III or better);
  • Hard disk with 3 Mbyte free space;
  • Flexible disk drive;
  • Operating system Windows 95/98/2000;
  • GA or VGA video monitor;
  • Graphic printer.
  • 64 Mb of RAM (128 Mb recommended).

Product benefited by the Informatics Legislation. (Article 48 of Decree No. 5.906 / 06).

Download

Software 64bits

Software 32bits

ELO 71

Software developed for the purpose of reading and programming the standard ABNT meters

ELO.71 is software that allows the user to program and read ABNT standard electronic meters. Both programming and reading are done through a direct connection of the microcomputer running the ELO.71 with the meter through the serial port of this microcomputer.

All parameter setting and meter reading features are available in a comfortable and intuitive way. ELO.71 is an important tool, which includes the latest meter change commands on the well-known Windows platform.

ELO.71 also allows another important operation: viewing the fiscal page in real time to see how the meter is installed.

Comes with communication cable Meter-Computer.

Installation Requirements

  • PC-type microcomputer (Pentium III or better);
  • Hard disk with 5 Mbyte free space;
  • Flexible disk drive;
  • Operating system Windows 95/98/2000 / XP;
  • VGA video monitor;
  • Serial USB or RS232 port;
  • 64 Mb of RAM (128 Mb recommended).

Product benefited by the Informatics Legislation. (Article 48 of Decree No. 5.906 / 06).

Download

Software 64bits

Software 32bits